Manufacturer | Sperre |
Model | LL2/140 |
Serial number | 145084 |
kW | 30 |
RPM | 1470 |
Volt | 380/660 |
HZ | 50 |
m³ /h, cubic meter per hour capacity | 188 |
Electric motor type | Stromberg hxur 405A2 B3 |
Working pressure BAR | 8 |
Test Pressure BAR | 15 |
Model LL2/140 is a one stage 90º V-compressor.
Cylinders and compressed air coolers are air-cooled.
Bearings and cylinders walls are splash lubricated. The compressor and motor are normally supplied mounted together and connected by means of a heavy-duty flexible coupling.
Technical Data | ||||
---|---|---|---|---|
Performance | 50 Hz (7-10 bar) | 60 Hz (7-10 bar) | ||
Speed (RPM) | 975 | 1475 | 1175 | |
Charging capacity (m³/h)* | 128 | 188 | 155 | |
Power requirement (kW) | 16,5 | 25,1 | 19,8 | |
Heat dissipation (kCal/h) | 12771 | 19427 | 15325 | |
*Charging capacity is from ambient pressure to final pressure. Tolerance +/-5%. | ||||
Design | ||||
No. of cylinders | 2 | |||
Cylinder arrangement | 90° V | |||
No. of compression stages | 1 | |||
Cooling | Air | |||
Valve LP | Concentric plate valves | |||
Dimensions & weight | ||||
Cylinder diameter LP | 140 mm | |||
Stroke | 100 mm | |||
Weight (compressor/el.motor) | 626 kg | |||
Lubrication | ||||
Sump capacity | 10 litres | |||
Lubrication system | Splash | |||
Operating parameters | ||||
Maximum delivery pressure | 10 bar | |||
Ambient temperature | 45°C | |||
Normal temperature outlet air | 10°C above ambient temperature | |||
Maximum speed | 1500 RPM | |||
Set point thermo switch air alarm/stop | 75°C/80°C | |||
Rotation | Anti-clockwise (looking at the drive end) | |||
Safety valves set point | 10% above stage pressure | |||
Max. noise level | 91 dBA | |||
Max. vibration level | 30 mm/s-RMS |